Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

ÇDZâ¹é Àΰø¼öÁ¤Ã¼¸¦ ÀÌ¿ëÇÑ ¹é³»Àå ¼ö¼ú ÈÄÀÇ ÀÜÁ¸ ±¼Àý ÀÌ»óÀÇ ±³Á¤ 1¿¹

A Case of Corrected Residual Refractive Error after Cataract Surgery with the Sulcoflex Piggyback IOL

´ëÇѾȰúÇÐȸÁö 2014³â 55±Ç 12È£ p.1890 ~ 1894
ÀÌÁ¾¼ö ( Lee Jong-Soo ) - ºÎ»ê´ëÇб³ ÀÇÇÐÀü¹®´ëÇпø ¾È°úÇб³½Ç

±è¿µÈñ ( Kim Young-Hi ) - ¹àÀº´«¾È°úº´¿ø
¹ÚÁ¤¿­ ( Park Jung-Yul ) - ºÎ»ê´ëÇб³ ÀÇÇÐÀü¹®´ëÇпø ¾È°úÇб³½Ç
±è¼ºÀÏ ( Kim Sung-Il ) - ºÎ»ê´ëÇб³ ÀÇÇÐÀü¹®´ëÇпø ¾È°úÇб³½Ç

Abstract

¸ñÀû: ¹é³»Àå ¼ö¼ú ÈÄÀÇ ÀÜÁ¸ ±¼Àý ÀÌ»óÀ» piggyback ¹æ½ÄÀÇ Sulcoflex Àΰø¼öÁ¤Ã¼¸¦ ÀÌ¿ëÇØ ±³Á¤ÇÑ 1¿¹¿¡ ´ëÇØ º¸°íÇϰíÀÚ ÇÑ´Ù.

Áõ·Ê¿ä¾à: 77¼¼ ³²ÀÚ È¯ÀÚ°¡ ¿ì¾ÈÀÇ °ú¼÷¹é³»ÀåÀ¸·Î Áø´Ü¹Þ¾ÒÀ¸¸ç, ¼ö¼ú Àü ±³Á¤½Ã·ÂÀº ¾ÈÀü¼öÁö¿´´Ù. ¿ì¾ÈÀÇ °í½ÄÀûÀÎ ¹é³»Àå ¼ö¼ú ÈÄ 6°³¿ù µÚ ±¼ÀýÀÌ»óÀº +9.0µð¿ÉÅÍ·Î ÃøÁ¤µÇ¾ú´Ù. À̸¦ ±³Á¤Çϱâ À§ÇÑ ÀÌÂ÷ ¼ö¼úÀÌ ÇÊ¿äÇÏ´Ù°í ÆÇ´ÜµÇ¾î +10.0µð¿ÉÅÍÀÇ Sulcoflex Àΰø¼öÁ¤Ã¼¸¦ piggyback ¹æ½ÄÀ» ÀÌ¿ëÇÏ¿© ¼¶¸ðü°í¶û¿¡ À§Ä¡½ÃÄ×´Ù. ¼ö¼ú 4ÁÖ ÈÄ¿¡ ÃøÁ¤ÇÑ ±¼ÀýÀÌ»óÀº -1.25µð¿ÉÅÍ¿´À¸¸ç, ³ª¾È½Ã·Â Àº 0.32, ±³Á¤½Ã·ÂÀº 0.63À¸·Î Çâ»óµÇ¾ú°í ȯÀÚ´Â ÀÌÂ÷ ¼ö¼ú¿¡ ´ëÇØ ¸¸Á·ÇÏ¿´À¸¸ç, °æ°ú °üÂû ±â°£ Áß ÇÕº´ÁõÀº °üÂûµÇÁö ¾Ê¾Ò´Ù.

°á·Ð: º» Áõ·Ê¸¦ ÅëÇØ Sulcoflex Àΰø¼öÁ¤Ã¼¸¦ ÀÌ¿ëÇÑ ¹é³»Àå ¼ö¼ú ÈÄÀÇ ÀÜÁ¸ ±¼Àý ÀÌ»óÀÇ ±³Á¤ÀÌ ¾ÈÀüÇϸç À¯¿ëÇÔÀ» ¾Ë ¼ö ÀÖ¾ú´Ù.

Purpose: To report a case of corrected residual refractive error after cataract surgery with sulcoflex piggyback intraouclar lens (IOL).

Case summary: A 77-year-old man was diagnosed as having hypermature cataract in the right eye and his corrected visual acuity in the same eye was hand-motion before surgery. Refractive error was +9.0 diopter (D) 6 months after conventional cataract surgery in the right eye. The authors performed additional cataract surgery using a piggyback method inserting a +10.0 D IOL in the ciliary sulcus. Four weeks after surgery, his refractive error was -1.25 D, visual acuity increased to 120/200 and 60/200 (with and without correction, respectively). No complication was observed during follow-up time and the patient was satisfied with his results.

Conclusions: Correction of residual refractive error after cataract surgery with sulcoflex piggyback IOL is safe and effective.

Ű¿öµå

Cataract surgery; Piggyback; Residual refractive error; Sulcoflex IOL