Removal of a Trigger Cord Stuck between Bands during Endoscopic Multiple-Band Ligation for Treating Esophageal Variceal Hemorrhage

Clinical Endoscopy 2020년 53권 2호 p.230 ~ 231
함남석, 이단비, Won Sung-Hyun, 김정석, 조석정, 이상영, 소설,
소속 상세정보
함남석 ( Ham Nam-Seok ) - University of Ulsan College of Medicine Asan Medical Center Department of Gastroenterology
이단비 ( Lee Dan-Bi ) - University of Ulsan College of Medicine Asan Medical Center Department of Gastroenterology
 ( Won Sung-Hyun ) - University of Ulsan College of Medicine Asan Medical Center Department of Gastroenterology
김정석 ( Kim Jeong-Seok ) - University of Ulsan College of Medicine Asan Medical Center Department of Gastroenterology
조석정 ( Jo Seok-Jung ) - University of Ulsan College of Medicine Asan Medical Center Department of Gastroenterology
이상영 ( Yi Sang-Young ) - University of Ulsan College of Medicine Asan Medical Center Department of Internal Medicine
소설 ( So Seol ) - University of Ulsan College of Medicine Asan Medical Center Department of Gastroenterology

Abstract


Endoscopic variceal ligation is the preferred endoscopic treatment method for esophageal variceal bleeding. The incidence of complications such as chest pain, bleeding, stricture formation, and aspiration pneumonia is low. We report a case wherein a malfunctioning multiple-band ligator could have potentially caused damage to the esophageal varices and massive bleeding. The equipment was safely removed using scissors and forceps. To the best of our knowledge, this is the first published report detailing the management of a case of esophageal variceal bleeding.

키워드

Esophageal varix; Endoscopic variceal ligation; Complication