Predictive Value of BI-RADS Category 4A and 4B Lesions Detected on Breast Ultrasonography: Single Center Experience

Journal of Surgical Ultrasound 2020년 7권 2호 p.55 ~ 61
김은영, 배현수, 이성렬, 윤지섭, 박용래, 박찬흔,
소속 상세정보
김은영 ( Kim Eun-Young ) - Sungkyunkwan University School of Medicine Kangbuk Samsung Hospital Department of Surgery
배현수 ( Bae Hyun-Soo ) - Sungkyunkwan University School of Medicine Kangbuk Samsung Hospital Department of Surgery
이성렬 ( Lee Sung-Ryol ) - Sungkyunkwan University School of Medicine Kangbuk Samsung Hospital Department of Surgery
윤지섭 ( Yun Ji-Sup ) - Sungkyunkwan University School of Medicine Kangbuk Samsung Hospital Department of Surgery
박용래 ( Park Yong-Lai ) - Sungkyunkwan University School of Medicine Kangbuk Samsung Hospital Department of Surgery
박찬흔 ( Park Chan-Heun ) - Sungkyunkwan University School of Medicine Kangbuk Samsung Hospital Department of Surgery

Abstract


Purpose: The malignancy rates within the Breast Imaging Reporting and Data System (BI-RADS) category 4a and 4b lesions were examined, and the correlations with the histopathology results were analyzed. In addition, the positive predictive value (PPV) and clinical utility of BIRADS category 4a and 4b lesions for predicting a malignancy were assessed.

Methods: From January 2017 to December 2019, patients with BI-RADS category 4a and 4b lesions on breast ultrasonography (US) who underwent a subsequent core needle biopsy in the authors’ institution were evaluated. The clinical, pathological, and sonographic features were assessed to identify the malignancy rate and pathologic factors predictive of malignancy. The sensitivity, specificity, PPV, and negative predictive value (NPV) were calculated. A Binary logistic regression test was used to estimate the odds ratio (OR) and 95% confidence interval (CI).

Results: The study population included 314 lesions in 275 patients (mean age, 45.3 years; range, 21?78 years). The overall malignancy rate was 9.8% (31 of 314). The malignancy rates among the BI-RADS category 4a and 4b lesions were 9.3% (28 out of 300) and 21.4% (3 out of 14), respectively. Compared to the well-defined margins, ill-defined margins were associated with an increased risk of breast cancer with a corresponding OR (95% CI) of 1.880 (1.304-2.554). The sensitivity, specificity, PPV, and NPV of the C4a and C4b lesions were as follows: 90.3%, 3.9%, 9.4%, and 78.6%, respectively, for C4a lesions and, 9.7%, 96.1%, 21.4%, and 90.6%, respectively, for C4b lesions. Only the equivocal elasticity on ultrasonography was associated with an increased risk of breast cancer with an OR (95% CI) of 2.357 (1.004-5.532).

Conclusion: BI-RADS categories 4a and 4b are useful for predicting malignancy. Nevertheless, further studies will be needed to identify more predictive factors for breast cancer.