全身麻醉中 動靜脈血中 氣體分壓 및 Ph의 比較硏究

Indirect Estimation of Arterial Po₂ and pH during General Anesthesia

대한마취과학회지 1976년 9권 1호 p.17 ~ 21
문경수, Robb, Ian S., 박중원,
소속 상세정보
문경수 (  ) - 연세대학교 의과대학 마취과학교실
 ( Robb, Ian S. ) - 연세대학교 의과대학 마취과학교실
박중원 (  ) - 연세대학교 의과대학 마취과학교실

Abstract


Many attempts have been made to device a simple, yet accurate, laboratory method to evaluate the ventilation and acid-base disorders in patients.
This study compares the values for Pco₂, pH and Po₂of blood samples drawn simultaneously from a radial artery and a vein on the back of the other hand during general anesthesia in 6 cases.
The mean arterial and mean venous Pco₂and pH differences were 0.924 torr and 0.00013. These differences were too small to be of clinical importance and also varies slightly dependent on the main anesthestics used. Therefore we feel that the use of peripheral venous blood for pH and Pco₂determination during general anesthesia is a reliable indirect method of arterial Pco₂and pH.

키워드

원문 및 링크아웃 정보

 

등재저널 정보

KCI
KoreaMed
KAMS